This guide walks through connecting Senceive devices to the platform using FTP file uploads. The Senceive system exports measurement files and periodically pushes them to an FTP server, which the platform then reads automatically.

Note: We recommend creating a Blueprint and your Sensors first, so that when you map the data source labels at the end of this guide, you have sensors to connect to.

1. Configure the Senceive portal to push via FTP

Log in to the Senceive device management / web portal and configure your project or deployment so that measurements are exported as files and automatically uploaded to an FTP server.

You do not need to write a program to do this; Senceive provides configuration options in its web portal to set:

  • FTP server hostname
  • Username and password
  • Remote directory / file path
  • Upload schedule or interval

Use the FTP server details that you have set up for the platform integration. Once configured, Senceive will regularly push updated data files to the FTP server.

2. Add a data connection

In the Sensly portal, add a data connection and choose FTP. Enter the FTP server credentials for the server where the Senceive portal uploads its files.

Senceive Data Connection

3. Add a data source

Under Data sources, create a new data source using the FTP connection you created.

Specify the file path where the Senceive portal uploads the data file.

Senceive Data Source

Set the schedule for when to check the FTP server for updated files.

Senceive Data Source Schedule

4. Map the file

Configure the file by selecting the File to map from the directory. If only one file is found, it will be auto-selected.

Note: If additional files appear in the File to map dropdown that you do not want processed, update the File match string on the data source details page to filter them out.

Select the Labels row (the row that identifies each column for matching to sensor inputs) and the Data row (where the data starts, so the header is not processed). These rows may vary depending on how Senceive formats your export file; choose the rows that match your file layout.

Select the Datetime column; the Datetime format will be auto-populated but can be edited if needed. The notation for datetime formats is described in 5. Datetime format in Data sources.

Senceive File Mapping

5. Map the sensor inputs

Map the platform sensor inputs to the corresponding columns in the Senceive data file (for example displacement, tilt, temperature, or water level).

Senceive Sensor Mapping

Once configured, the platform will automatically import new records from the uploaded files and update the sensor data.

Note: If additional sensors are mapped after a file has been processed, the data source will need to be re-run by reprocessing the data.